COMPRESSION COLUMN LOAD CELL FOR WEIGHBRIDGES/TRUCK SCALES

Compression Column Load Cell - ATL501 Analogue

  • Stainless Steel Rocker Column Analog Load cell
  • Self-centering column design with anti-rotation pin
  • 4000 Divisions OIML R60 Class C (C4)
  • Class III L NTEP approved
  • In-built surge arrestors for lightning protection
  • Hermetically welded and sealed to IP68 & IP69K
  • Combined Error < ± 0.013% of Rated Capacity
  • Compensated Temp range of 0 to +50 Deg C (Helps performing best at most demanding climatic conditions)
  • High durability Polyurethane cable (6 core, 18 mtr), provides resistance against harsh weather and aggressive chemicals, and protection against rodents etc.

This stainless steel self-centering rocker column load cell is fully welded and hermetically sealed, with protection to IP68/IP69K. It is an ideal solution for weighbridges/truck scales thanks to its approvals to OIML C4 (4000 divisions) and NTEP Class III L, as well as lightning surge arrestors and a tough, durable polyurethane cable. Corner correction at the junction box is minimised because the ATL501 is pre-corner adjustment optimised at +/- 0.05% by output current calibration (in mV/V/ Ω ). This saves a significant amount of time during commissioning. For use in weighbridges/truck scales, a range of mounting cup accessory sets are available as optional items, in either stainless steel or nickel plated alloy steel, along with a rubber gaiter, sealing clip and a set of centering discs. The ATL501 load cell also has application in silo, vessel and tank weighing, for which the ATL501 Silo Mount version is preferable. For applications in aggressive environments where stress corrosion or acid attack could be an issue, a special Parylene coating can be specified as an option. Also available are ATEX and High Temperature versions. While the ATEX certification allows use in all zones, in dust zones 20, 21, 22 and gas zone 2 there is no need for safety barriers.



  • Stainless steel load sensor
  • Fully welded and hermetically sealed to IP68/IP69K
  • In-built surge arrestors for lightning protection
  • Calibrated in mV/ V/ Ω for pre-corner adjustment optimisation
  • Simple installation
  • 3 year warranty
  • Self-centering rocker column design with anti-rotation pin
  • Approval to OIML R60 C4 (4000 divisions)
  • Approval to NTEP Class III L
  • Mounting cup accessories available
  • Mounting cup accessories available

ATL501 echnical specification...

Exhibition

ATL501 Load Cell

Load cell specification Units
Load Cell Capacities 15, 20, 30, 40, 60 tonnes
Rated Output 2 mV/ V **
Accuracy Class 4000 n.OIML
Combined error < +/- 0.013 %*
Non-repeatability < +/- 0.015 %*
Creep (30 minutes) < +/- 0.012 %*
Temperature Effect on Zero Balance < +/- 0.002 %* / ̊C
Temperature Effect on Span < +/- 0.0012 %* / ̊C
Compensated Temperature Range -10 to +40 ̊C
Operating Temperature Range -50 to +70 ̊C
Safe Overload 150 %*
Ultimate Overload 350 %*
Zero Balance < +/-2 %*
Input Resistance 800 Ω +/- 5
Output Resistance 705 Ω +/- 5
Insulation Resistance > 5000 M Ω @100v DC
Recommended Supply Voltage 10 V
Maximum Supply Voltage 15 V
Cable Length 20 m
Cable Material Polyurethane
Protection Class IP68/IP69K
15t, 20t 2.5 kg
30t 2.6 kg
40t 2.8 kg
60t 3.8 kg
Mounting Accessories 3 kg
Nominal Shipping Weight
* All percentages are related to Rated output
* Pre-corner adjustment optimised at +/- 0.05% by output current calibration

Dimensions

Capacity 15t 20t 25t 30t 40t 60t
A 200 200 200 200 200 260
B 150 150 150 150 150 210
C 123 123 123 123 123 153
d max. 13 13 13 13 13 11
e max. 5 5 5 5 5 3
r sph. radius 130 130 150 160 180 220
All dimensions are in mm
Exhibition

Model ATL501 ATEX Certification

Code Temperature Class Parameters Application
II 1 G D
Ex ia IIC T4...T6 Ga
Ex ia IIIC T135 °C...T85°C Da
Ex ta IIIC T85 °C Da
T6 for Gas Zones 0, 1, 2 85°C for Dust Zones 20, 21, 22 Pi = 1.3W Gas Zones 0, 1, 2 with
safety barriers.
Dust Zones 20, 21, 22
without
safety barriers.
T5 for Gas Zones 0, 1, 2 100°C for Dust Zones 20, 21, 22 Pi = 0.6W
T4 for Gas Zones 0, 1, 2 135°C for Dust Zones 20, 21, 22 Pi = 0.2W
II 3G D
Ex nA T6
Ex ta IIIC T85 °C Da/td>
T4 for Gas Zones 0, 1, 2 135°C for Dust Zones 20, 21, 22 Umax = 25 V Gas Zone 2 and Dust
Zone 22
without
safety
barriers.
Maximum excitation
voltage 25 V

Electrical Connections

Via 6 wire, 5.7mm diameter, screened polyurethane cable. Screen not connected electrically to load cell.
Construction Load cell manufactured from stainless steel
Options Mounting accessory set comprising stainless steel or nickel plated alloy steel top and bottom mounting cups, rubber gaiter and centering discs

Our policy is one of continuous product enhancement. We therefore reserve the right to incorporate technical modifications without prior notification.